Why deduction rules matter

Two engineers measuring the same building can get different quantities just by treating openings differently. IS 1200, the Indian Standard method of measurement of building and civil engineering works, sets common rules so that quantities in a BOQ can be checked and compared. Brickwork is covered in Part 3 and plastering in Part 12.

Brickwork (IS 1200 Part 3)

  • Openings up to 0.1 m² in area are not deducted.
  • Larger openings — doors, windows, ventilators — are deducted in full.
  • Concrete passing through the wall, such as lintels and beams, is deducted, since it's measured under its own item.
  • Small ends of beams, posts and similar members bearing on the wall are generally not deducted below a minimum section — check the clause for the limits.

Plastering (IS 1200 Part 12)

Opening areaDeductionJambs, soffits and sills
Up to 0.5 m²NoneNot added
0.5 m² to 3 m²One face onlyNot added
Over 3 m²Both facesAdded (measured)

The idea: for medium openings, the plaster saved on one face roughly balances the extra work on the jambs and sills, so one face is deducted and nothing is added. Large openings are deducted from both faces and the returns are measured separately.

Example: a 1.5 m × 1.2 m window

Window 1.5 × 1.2 = 1.8 m² in a 230 mm wall

  • Brickwork: 1.8 m² > 0.1 m², so deduct 1.8 × 0.23 = 0.414 m³
  • Plaster: 1.8 m² is between 0.5 and 3 m², so deduct 1.8 m² from one face only
  • Jambs and sill: not added

Your office's rules may differ

Many firms follow simplified rules — for example, deducting all openings over 0.5 m² from one face only, or deducting inside faces only where inside and outside plaster are separate items. What matters is applying one rule consistently and stating it with the BOQ.

Civiniq applies deductions by written rules you can see and change: your own, or an IS 1200 preset. Every deduction appears as a 'Less:' line in the measurement sheet, and the rules are printed with the exported BOQ.

This is a practical summary. Always check the current edition of IS 1200 and the mode of measurement in your contract.

FAQ

Common questions

Are openings up to 0.1 m² deducted from brickwork?

No. Under IS 1200 Part 3, openings up to 0.1 m² in area are not deducted from brickwork.

When are openings deducted from both faces of plaster?

Under IS 1200 Part 12, openings over 3 m² are deducted from both faces, and their jambs, soffits and sills are measured separately.

Are lintels deducted from brickwork?

Yes. Lintels and beams that pass through a wall are deducted from the brickwork and measured under their own concrete item.

Price your next model in minutes, not days.

Upload a Revit IFC and generate a priced BOQ with full measurement sheets. Free for 3 months — no credit card.