Guide
Revit to BOQ: how to generate a BOQ from a Revit model, step by step
How to turn a Revit model into a priced bill of quantities: the IFC export settings that matter, uploading, mapping element types and exporting the BOQ to Excel.
By Civiniq Civil Estimation 5 min read
Why the export settings matter
A Revit model already knows the size of every wall, slab and opening. Getting a BOQ from it takes two parts: exporting the model with the right information, and turning the measured elements into priced work items. An IFC file is only as useful as what was exported into it — for a BOQ, three things matter most: the measured quantities, the properties that describe each element (such as whether a wall is external), and every element sitting on the right floor.
Part 1 — Export the IFC from Revit
- Open the model and go to File → Export → IFC.
- Click Modify Setup. Select “IFC2x3 Coordination View 2.0 Setup” and duplicate it — for example as “BOQ export” — so the built-in setup stays untouched.
- General tab: keep IFC version IFC2x3 Coordination View 2.0 and file type IFC, and tick “Split Walls, Columns, Ducts by Level”.
- Property Sets tab: tick “Export IFC common property sets” and “Export base quantities”.
- Advanced tab: tick “Store the IFC GUID in an element parameter after export”, so elements keep the same ID between exports.
- Click OK, choose a file name and export.
What each setting does
| Setting | Why it matters |
|---|---|
| Export base quantities | Writes Revit's measured volumes, areas and lengths into the file. Without it there are no quantities to take off. |
| Export IFC common property sets | Includes properties like whether a wall is external, which decides inside and outside plaster. |
| Split Walls, Columns, Ducts by Level | A wall running through two floors is split, so each floor's BOQ gets its own part. |
| Store the IFC GUID | Keeps element IDs stable, so a revised model can be compared with the last one. |
Leave “Use Type name only for IFCType name” unticked — type names are what map elements to your work items.
Check the export
Open the IFC in a viewer and confirm that walls, slabs and doors are there, on the right levels, and that elements show quantities such as NetVolume or NetSideArea. If quantities are missing, “Export base quantities” wasn't ticked or a different setup was selected.
Civiniq runs these checks automatically when you upload: a file without base quantities is stopped with the exact setting to fix, and other problems — duplicates, elements without a level, doors outside walls — are listed in the model check.
Part 2 — From IFC to a priced BOQ
- Upload the .ifc file to your project. The model is read and checked in seconds.
- Review the model check: fix problems in Revit, leave elements out of the BOQ, or mark them OK.
- Map each element type — say, a 230 mm brick wall — to one of your work items. Clear matches are made for you, and every choice is remembered for the next model.
- Generate the BOQ. Quantities are measured floor by floor, openings and lintels are deducted, and linked items such as plaster, steel and shuttering are added.
- Export to Excel — abstract and measurement sheets — or share a read-only link with your client.
When the design changes, export again and upload the revision: your mappings carry over, so the new BOQ takes minutes.